      "System / catalog page": "65 Casement Window · p. 4",
      "Catalog U-values W/(m²·K)": "1.6 / 1.5; 1.35 / 1.3",
      "Wind": "Class 8",
      "Water": "Class 5",
      "Air": "Class 7",
      "Acoustic claim": ">40 dB"
    },
    {
      "System / catalog page": "72 Casement Window · p. 5",
      "Catalog U-values W/(m²·K)": "1.5 / 1.4; 1.4 / 1.3; 1.3 / 1.2",
      "Wind": "Class 8",
      "Water": "Class 5",
      "Air": "Class 8",
      "Acoustic claim": ">40 dB"
    },
    {
      "System / catalog page": "83 Flush Window · p. 6",
      "Catalog U-values W/(m²·K)": "1.4 / 1.3; 1.2 / 1.1; 1.0 / 0.9",
      "Wind": "Class 8",
      "Water": "Class 6",
      "Air": "Class 8",
      "Acoustic claim": ">40 dB"
    },
    {
      "System / catalog page": "85 Casement Window · p. 7",
      "Catalog U-values W/(m²·K)": "1.3 / 1.2; 1.15 / 1.05; 0.9 / 0.8",
      "Wind": "Class 9",
      "Water": "Class 6",
      "Air": "Class 8",
      "Acoustic claim": ">42 dB"
    },
    {
      "System / catalog page": "95 Casement Window · p. 8",
      "Catalog U-values W/(m²·K)": "1.1 / 1.0; 0.85 / 0.75",
      "Wind": "Class 9",
      "Water": "Class 6",
      "Air": "Class 8",
      "Acoustic claim": ">42 dB"
    },
    {
      "System / catalog page": "103 Tilt-and-Turn Window · p. 9",
      "Catalog U-values W/(m²·K)": "0.8 / 0.7",
      "Wind": "Class 9",
      "Water": "Class 6",
      "Air": "Class 8",
      "Acoustic claim": ">42 dB"
    },
    {
      "System / catalog page": "103 Micro-Vent Window · p. 10",
      "Catalog U-values W/(m²·K)": "0.8 / 0.7",
      "Wind": "Class 9",
      "Water": "Class 6",
      "Air": "Class 8",
      "Acoustic claim": ">42 dB"
    },
    {
      "System / catalog page": "114 Curtain-Wall Window · p. 11",
      "Catalog U-values W/(m²·K)": "0.9 / 0.8",
      "Wind": "Class 9",
      "Water": "Class 6",
      "Air": "Class 8",
      "Acoustic claim": ">42 dB"
    },
    {
      "System / catalog page": "Insulated Entrance Door · p. 12",
      "Catalog U-values W/(m²·K)": "0.8",
      "Wind": "Class 9",
      "Water": "Class 6",
      "Air": "Class 8",
      "Acoustic claim": ">42 dB"
    },
    {
      "System / catalog page": "132 Lift-and-Slide Door · p. 13",
      "Catalog U-values W/(m²·K)": "1.4 / 1.3",
      "Wind": "Class 9",
      "Water": "Class 5",
      "Air": "Class 7",
      "Acoustic claim": ">40 dB"
    },
    {
      "System / catalog page": "145 Side-Pressure Door · p. 14",
      "Catalog U-values W/(m²·K)": "1.3 / 1.2",
      "Wind": "Class 9",
      "Water": "Class 5",
      "Air": "Class 7",
      "Acoustic claim": ">40 dB"
    }
  ],
  "notes": [
    "Paired U-value conditions are not defined in the reference data. Do not interpret the pair as a range or assign its values to air/argon fill. Confirm the selected assembly and glazing.",
    "Wind, water and air classes have no stated test standard. Acoustic entries retain > and have no stated Rw, STC or OITC method; no international class conversion is implied.",
    "Catalog values do not establish independent certification or project acceptance. Series numbers are identifiers, and the separate 80 / 90 / 140 profile collection is not included."
  ],
  "sources": [
    {
      "label": "Finished window and door catalog, pages 4–14",
      "href": "/downloads/catalogs/pultrx-finished-windows-doors-catalog-2026-11.pdf"
    },
    {
      "label": "Catalog definitions and performance limitations",
      "href": "/windows-doors/finished#glazing"
    }
  ]
}