Skip to content
pultrx

Window buyers preparing a shortlist and configuration-specific document review · Updated 2026-11-07

Finished Window Comparison Data

Download finished window comparison data for 11 pultrx systems. Retains catalog U-value pairs, wind, water and air classes, acoustic claims and source-page references.

Comparison table for 11 pultrx finished window and door systems preserving catalog U-value pairs, performance classes and acoustic claims
Finished window catalog data · Read the full instructions and notes below.Download image

Use this reference for your project

This finished window comparison data table reproduces catalog entries for eight pultrx windows and three door systems. Each row identifies the source page in the November 2026 finished-unit catalog.

U-value entries follow the glazing-configuration order on that catalog page. A semicolon separates configurations; a slash preserves a published pair. Consult the full glazing build-up before selecting a configuration.

How to use it

  1. 01

    Select the full name

    Identify the opening type and system name; a series number is not a confirmed frame depth.

  2. 02

    Check the glazing

    Match each U-value entry to its same-order glazing configuration on the cited catalog page.

  3. 03

    Request the evidence

    Obtain the applicable test or calculation basis for the proposed size, glass and hardware.

  4. 04

    Complete the schedule

    Record opening dimensions, quantities, handing and agreed performance requirements.

Catalog comparison data

Read the catalog conditions and the notes below before comparing values. The downloadable data preserves this reference table.

Finished Window Comparison Data: System / catalog page, Catalog U-values W/(m²·K), Wind, Water, Air, Acoustic claim
System / catalog pageCatalog U-values W/(m²·K)WindWaterAirAcoustic claim
65 Casement Window · p. 41.6 / 1.5; 1.35 / 1.3Class 8Class 5Class 7>40 dB
72 Casement Window · p. 51.5 / 1.4; 1.4 / 1.3; 1.3 / 1.2Class 8Class 5Class 8>40 dB
83 Flush Window · p. 61.4 / 1.3; 1.2 / 1.1; 1.0 / 0.9Class 8Class 6Class 8>40 dB
85 Casement Window · p. 71.3 / 1.2; 1.15 / 1.05; 0.9 / 0.8Class 9Class 6Class 8>42 dB
95 Casement Window · p. 81.1 / 1.0; 0.85 / 0.75Class 9Class 6Class 8>42 dB
103 Tilt-and-Turn Window · p. 90.8 / 0.7Class 9Class 6Class 8>42 dB
103 Micro-Vent Window · p. 100.8 / 0.7Class 9Class 6Class 8>42 dB
114 Curtain-Wall Window · p. 110.9 / 0.8Class 9Class 6Class 8>42 dB
Insulated Entrance Door · p. 120.8Class 9Class 6Class 8>42 dB
132 Lift-and-Slide Door · p. 131.4 / 1.3Class 9Class 5Class 7>40 dB
145 Side-Pressure Door · p. 141.3 / 1.2Class 9Class 5Class 7>40 dB

Scope and reading notes

  • Paired U-value conditions are not defined in the reference data. Do not interpret the pair as a range or assign its values to air/argon fill. Confirm the selected assembly and glazing.
  • Wind, water and air classes have no stated test standard. Acoustic entries retain > and have no stated Rw, STC or OITC method; no international class conversion is implied.
  • Catalog values do not establish independent certification or project acceptance. Series numbers are identifiers, and the separate 80 / 90 / 140 profile collection is not included.

Sources and supporting references

Prepared by pultrx from the references below. Follow the linked product or guide for the full scope and source conditions.