Geometry & mass
What are the nominal section properties and unit weight of 100 × 50 × 6 mm FRP I-beam?
Calculated from nominal millimetre dimensions before corner-fillet deductions, alongside equivalent S275 steel and 6063-T6 aluminum masses.
| Property | Metric value | Imperial / engineering note |
|---|---|---|
| Nominal designation | 100 × 50 × 6 mm | Depth × flange × wall (mm) |
| Inch equivalent | 3.94 × 1.97 in | Converted at 25.4 mm/in |
| Cross-sectional area (A) | 1,128 mm² | 1.75 in² (sharp-corner nominal) |
| FRP unit mass (at 1.9 g/cm³) | 2.14 kg/m | 1.44 lb/ft planning weight |
| Same-size S275 carbon steel mass | 8.85 kg/m | FRP saves 76% deadweight |
| Same-size 6063-T6 aluminum mass | 3.05 kg/m | FRP is 30% lighter than aluminum |
| Major-axis second moment (Ixx) | 166.8 cm⁴ | 4.01 in⁴ |
| Minor-axis second moment (Iyy) | 12.7 cm⁴ | Ratio Ixx / Iyy = 13.18 |
| Elastic section modulus (Sxx / Syy) | 33.4 / 5.1 cm³ | Extreme-fibre bending modulus |
| Radius of gyration (rx / ry) | 38.5 / 10.6 mm | Used for axial column slenderness L/r |
| External perimeter | 388 mm | Surface veil and coating perimeter |
| Tooling status | Existing die (partner factory) | Pultruded to order; no new die charge |
Gross area equals 1,128 mm² and nominal weight is 2.14 kg/m (1.44 lb/ft) at 1.9 g/cm³, matching the 100 × 50 × 6 mm channel gram-for-gram while weighing 76 percent less than steel (8.85 kg/m) and 30 percent less than aluminum (3.05 kg/m).
While major-axis properties reach Ixx = 166.8 cm⁴, Sxx = 33.4 cm³ and rx = 38.5 mm, splitting the 50 mm flange symmetrically across the web yields narrow 22 mm flange outstands and modest minor-axis values of Iyy = 12.7 cm⁴, Syy = 5.1 cm³ and ry = 10.6 mm.
Preliminary stiffness check
How much does 100 × 50 × 6 mm FRP I-beam deflect across typical spans under E17 and E23 grades?
Euler bending estimates about the major axis (Ixx = 166.8 cm⁴) under a 1.2 kN/m uniform line load, comparing EN 13706-2 Grade E17 (17 GPa) and Grade E23 (23 GPa) minimum longitudinal moduli.
| Simple span (L) | Deflection at 1.2 kN/m (E17: 17 GPa) | Deflection at 1.2 kN/m (E23: 23 GPa) | Load for L/180 (E23) | Load for L/240 (E23) |
|---|---|---|---|---|
| 1.2 m (1200 mm) | 1.1 mm (L/1050) | 0.8 mm (L/1421) | 9.47 kN/m | 7.10 kN/m |
| 1.8 m (1800 mm) | 5.8 mm (L/311) | 4.3 mm (L/421) | 2.81 kN/m | 2.10 kN/m |
| 2.4 m (2400 mm) | 18.3 mm (L/131) | 13.5 mm (L/178) | 1.18 kN/m | 0.89 kN/m |
Under a 1.2 kN/m uniform load at 23 GPa modulus, pure Euler deflection measures roughly 0.8 mm at 1.2 m span, 4.3 mm at 1.8 m (L/421) and 13.5 mm at 2.4 m (L/178) when the top flange is laterally restrained.
Because minor-axis radius of gyration ry is only 10.6 mm (giving Ixx/Iyy = 13.1), an unbraced compression flange buckles laterally well before the 2.4 m deflection limit is reached unless molded grating saddle clips or cross-blocking brace the top flange every 450 to 600 mm.
At 1.2 m short sump spans (L/h = 12), web shear deformation adds roughly 14 to 17 percent onto the Euler bending figure; include both terms when sizing tight-clearance scrubber internals.
Run point loads, cantilevers or shear-corrected Timoshenko checks in the FRP section properties & deflection calculator, and verify material grade testing in EN 13706 & ASTM D3917 profile standards.
Fasteners & mating tolerances
How do you connect a 50 mm narrow-flange I-beam without weakening the 22 mm outstands?
Each side of the 50 mm flange projects only 22 mm past the 6 mm central web, which is too narrow for standard M10 or M12 through-bolts once internal web-flange fillets and edge-distance rules are respected. Instead of drilling flange outstands, clamp floor grating with top-saddle M-clips that straddle the 50 mm flange or use under-flange J-clips.
At beam ends, transfer shear through double clip angles (such as 50 × 50 × 6 mm FRP angle cleats) bolted across the 88 mm clear web height with M10 stainless bolts, supplementing seated bearings with web-stiffening blocks where point reactions exceed 6 kN.
| Interface or feature | Drawing & assembly specification |
|---|---|
| Flange outstand width | 50 mm overall flange leaves 22 mm each side of the 6 mm web; fasten with clamp-over grating clips rather than flange bolt holes. |
| Clear web zone | 88 mm vertical flat between flanges; accepts double-sided M10 web shear cleats at girder intersections. |
| Bearing seat length | Provide 50 to 65 mm flat end bearing on sump ledges and restrain top-flange rollover at supports with end clip angles. |
| Lateral brace spacing | Keep unbraced compression-flange length below 50 × ry (roughly 530 mm) via grating clips or diaphragm struts. |
Shop tooling, diamond blades and bonded-bolted joint layout: how to cut, drill and join fiberglass profiles.
Request a quotation
Get a quotation for 100 × 50 × 6 mm FRP I-beam
Send your cut lengths, piece count, resin system and destination port. An engineer in Shanghai reviews the schedule and replies in English.
Prefer email or chat? Write to inquiry@pultrx.com or message Celion on WhatsApp. Drawings can follow by email.
Service environments & resin selection
Where is 100 × 50 × 6 mm FRP I-beam used in treatment tanks and chemical sumps?
Chemical neutralization pits, battery-room floor trenches and wet FGD scrubber towers set 100 × 50 × 6 mm vinyl ester I-beams at 600 to 900 mm centers across 1.2 to 2.0 m sump widths to carry 38 mm molded grating or polypropylene mist-eliminator packs. Centered loading keeps narrow trench beams plumb without tipping on elastomeric bearing pads.
If your connection layout requires bolting directly through beam flanges or spanning unbraced gaps without continuous grating clips, switch to the wider-flange 80 × 78 × 6 mm or 102 × 102 × 8 mm existing H-section dies in our partner factories' catalog. For spans above 2.2 m under walkway loads, step up to the 159 × 88 × 6/10 mm or 200 × 100 × 10 mm I-beams.
Compare adjacent metric dies
Other metric i-beam engineering sheets
FAQ
What do buyers ask before ordering 100 × 50 × 6 mm FRP I-beam?
Can I drill bolt holes through the 50 mm flanges of a 100 × 50 × 6 mm FRP I-beam?
Drilling the 22 mm flange outstands is strongly discouraged because even an 8.5 mm hole for an M8 bolt violates minimum edge-distance and fillet-clearance margins, cutting longitudinal roving continuity right where bending stress peaks. Use straddle saddle clips on the top flange and bolted angle cleats on the 88 mm web instead.
When is this 100 × 50 × 6 mm I-beam better than the 100 × 50 × 6 mm channel?
Pick the 100 × 50 × 6 mm I-beam whenever the member acts as an interior joist loaded down its centerline by floor grating on both sides, since its symmetric cross-section eliminates torsional twist. Reserve the 100 × 50 × 6 mm channel for perimeter curbs and wall ledgers that bolt flat against vertical concrete.
How should mist-eliminator support beams be seated on concrete sump ledges?
Seat each beam end on a 6 mm EPDM or neoprene bearing pad at least 60 mm long so rough concrete ledges never abrade the bottom synthetic veil. Add side-restraint angles against the 6 mm web so thermal expansion slides axially without letting the 100 mm deep section roll.
Can point loads hang from the bottom flange of a 100 × 50 × 6 mm I-beam?
Avoid suspending heavy pipe hangers from the bottom flange alone because transverse pull-off places the web-to-flange roving junction in interlaminar tension, which is the lowest strength axis of any pultruded I-section. Wrap hanger straps over the top flange or bolt suspension clevises through the vertical web.
Is tooling already available for 100 × 50 × 6 mm FRP I-beam?
Yes, 100 × 50 × 6 mm runs on an existing I-beam die in our partner-factory network with no tooling lead time. Specify isophthalic polyester or vinyl ester resin and required cut lengths on your purchase order.