Geometry & mass
What are the nominal section properties and unit weight of 210 × 80 × 5 mm FRP channel?
Calculated from nominal millimetre dimensions before corner-fillet deductions, alongside equivalent S275 steel and 6063-T6 aluminum masses.
| Property | Metric value | Imperial / engineering note |
|---|---|---|
| Nominal designation | 210 × 80 × 5 mm | Depth × flange × wall (mm) |
| Inch equivalent | 8.27 × 3.15 in | Converted at 25.4 mm/in |
| Cross-sectional area (A) | 1,800 mm² | 2.79 in² (sharp-corner nominal) |
| FRP unit mass (at 1.9 g/cm³) | 3.42 kg/m | 2.30 lb/ft planning weight |
| Same-size S275 carbon steel mass | 14.13 kg/m | FRP saves 76% deadweight |
| Same-size 6063-T6 aluminum mass | 4.86 kg/m | FRP is 30% lighter than aluminum |
| Major-axis second moment (Ixx) | 1174.0 cm⁴ | 28.21 in⁴ |
| Minor-axis second moment (Iyy) | 105.4 cm⁴ | Ratio Ixx / Iyy = 11.14 |
| Elastic section modulus (Sxx / Syy) | 111.8 / 17.3 cm³ | Extreme-fibre bending modulus |
| Radius of gyration (rx / ry) | 80.8 / 24.2 mm | Used for axial column slenderness L/r |
| External perimeter | 730 mm | Surface veil and coating perimeter |
| Tooling status | Existing die (partner factory) | Pultruded to order; no new die charge |
A 1,800 mm² cross-section yields 3.42 kg/m (2.30 lb/ft) at 1.9 g/cm³, virtually matching the 3.40 kg/m mass of a 150 × 60 × 7 mm channel while more than doubling major-axis inertia (1,174.0 vs 576.5 cm⁴); steel and aluminum equivalents weigh 14.13 kg/m and 4.86 kg/m.
Section moduli reach Sxx = 111.8 cm³ and Syy = 17.3 cm³ (Iyy = 105.4 cm⁴), with radii of gyration rx = 80.8 mm and ry = 24.2 mm across the 200 mm clear web depth.
Preliminary stiffness check
How much does 210 × 80 × 5 mm FRP channel deflect across typical spans under E17 and E23 grades?
Euler bending estimates about the major axis (Ixx = 1174.0 cm⁴) under a 1.5 kN/m uniform line load, comparing EN 13706-2 Grade E17 (17 GPa) and Grade E23 (23 GPa) minimum longitudinal moduli.
| Simple span (L) | Deflection at 1.5 kN/m (E17: 17 GPa) | Deflection at 1.5 kN/m (E23: 23 GPa) | Load for L/180 (E23) | Load for L/240 (E23) |
|---|---|---|---|---|
| 2.0 m (2000 mm) | 1.6 mm (L/1277) | 1.2 mm (L/1728) | 14.40 kN/m | 10.80 kN/m |
| 3.0 m (3000 mm) | 7.9 mm (L/378) | 5.9 mm (L/512) | 4.27 kN/m | 3.20 kN/m |
| 4.0 m (4000 mm) | 25.1 mm (L/160) | 18.5 mm (L/216) | 1.80 kN/m | 1.35 kN/m |
Under a 1.5 kN/m uniform gravity or wind line load at 23 GPa modulus, restrained Euler mid-span deflection stays near 1.2 mm at 2.0 m, 5.9 mm at 3.0 m (L/512) and 18.5 mm at 4.0 m (L/216).
Clear web slenderness hits h/t = 200 / 5 = 40 and flange outstand slenderness reaches 15, so web crippling at rafter seats and local compression-flange buckling under wind uplift govern allowable load well ahead of flexural fiber rupture.
Because the shear center sits well behind the 210 mm web, sloped roof purlins require bolted rafter web cleats at every support plus one or two rows of anti-sag rods across 3.0 to 4.0 m bays so roof sheeting fasteners are spared torsional prying.
Run point loads, cantilevers or shear-corrected Timoshenko checks in the FRP section properties & deflection calculator, and verify material grade testing in EN 13706 & ASTM D3917 profile standards.
Fasteners & mating tolerances
How do you detail rafter cleats and anti-sag ties on a 5 mm web 210 × 80 mm purlin?
Never seat a 210 × 80 × 5 mm channel directly on its 5 mm bottom flange over a rafter without bolting the 200 mm flat web to a full-height vertical rafter cleat; direct bearing on the thin web alone risks local web crippling. Use a 160 to 180 mm tall FRP or hot-dip/stainless steel web cleat fastened with three M12 bolts at 60 mm vertical centers.
Where wind uplift puts the bottom flange into unbraced compression, run diagonal stay braces from the lower web region back to the roof cladding or bolt two 210 × 80 × 5 mm channels back-to-back over high-suction eave bays.
| Interface or feature | Drawing & assembly specification |
|---|---|
| Web slenderness & height | 200 mm clear web height (h/t = 40); reinforce concentrated bearing seats with full-depth bolted rafter cleats. |
| 80 mm flange table | Wide 80 mm top flange accepts self-drilling composite roof screws (with EPDM bonded washers) or M10 solar rail clamps on a 45 mm gauge. |
| Anti-sag rod holes | Punch or drill 13 mm web holes near the upper third point at mid-span for M12 tubular-sleeved sag rods on pitched roofs. |
| Adjacent 210 mm family | Shares 210 mm web cleat hole patterns with narrower 210 × 55 × 5 mm and wider 210 × 85 × 5 mm existing dies. |
Shop tooling, diamond blades and bonded-bolted joint layout: how to cut, drill and join fiberglass profiles.
Request a quotation
Get a quotation for 210 × 80 × 5 mm FRP channel
Send your cut lengths, piece count, resin system and destination port. An engineer in Shanghai reviews the schedule and replies in English.
Prefer email or chat? Write to inquiry@pultrx.com or message Celion on WhatsApp. Drawings can follow by email.
Service environments & resin selection
Where does 210 × 80 × 5 mm channel excel in corrosive roofs and solar mounting?
Fertilizer storage sheds, potash warehouses, pickling bays and coastal wastewater tank covers replace cold-formed galvanized Z/C purlins with 210 × 80 × 5 mm FRP channels so rising acid vapor or ammonia condensation cannot rust roof framing overhead. Utility-scale and industrial rooftop solar integrators also use the wide 80 mm flange as non-conductive primary module rails across 3.0 to 3.8 m pile spacings.
Within the 210 mm purlin series held in our partner factories' existing dies, 210 × 55 × 5 mm suits lighter wall girts while 210 × 85 × 5 mm adds 5 mm extra flange width at roof expansion joints. If roofs lack diaphragm sheeting to restrain an open C-section against twist, consider closed 55 × 160 × 4 mm or 55 × 220 × 4 mm rectangular purlin tubes instead.
Compare adjacent metric dies
Other metric channel engineering sheets
- 100 × 50 × 6 mm FRP channelCompact 100 × 50 × 6 mm pultruded C-channel (2.14 kg/m, Ixx 166.8 cm⁴, 88 mm clear web) used for heavy cable tray side rails, clarifier weir framing and equipment rim trim.
- 120 × 65 × 6 mm FRP channelWide-flange 120 × 65 × 6 mm pultruded C-channel (2.71 kg/m, Ixx 316.6 cm⁴, 108 mm clear web) proportioned for platform framing joists, pipe-support headers and chemical process skids.
- 150 × 60 × 7 mm FRP channelThick-walled 150 × 60 × 7 mm pultruded C-channel (3.40 kg/m, Ixx 576.5 cm⁴, 136 mm clear web) built for industrial stair stringers, coastal jetty edge trim and braced walkway joists.
FAQ
What do buyers ask before ordering 210 × 80 × 5 mm FRP channel?
Can roof cladding screws thread directly into the 5 mm top flange without pull-out?
Self-tapping screws alone have limited thread engagement in a 5 mm pultruded flange under cyclonic wind uplift. High-wind roofs and solar module clamps should use through-bolted M8 or M10 stainless J-bolts, T-bolts or backing washers underneath the 80 mm flange rather than relying on shallow cut threads.
How do you prevent web crippling where 210 × 80 × 5 mm purlins cross primary rafters?
Transfer the purlin reaction through vertical shear bolts in a tall rafter cleat bolted across the middle 120 to 160 mm of the web rather than resting the bottom flange unreinforced on the rafter cap. That shear-cleat detail engages the full 210 mm web in shear and prevents localized buckling above the support.
Does solar racking in 210 × 80 × 5 mm FRP eliminate array grounding hardware?
Pultruded E-glass framing is electrically non-conductive, so individual aluminum PV module frames still require equipment-grounding lugs or bonding clips per local electrical codes. By contrast, the primary FRP racking rails themselves never form stray ground loops or corrode against dissimilar soil piles.
Should two 210 × 80 × 5 mm channels be lapped or sleeved over continuous multi-span rafters?
Unlike thin cold-formed steel Z-purlins that nest inside one another, constant-dimension FRP C-channels butt squarely over rafters and achieve continuity via a double-bolted web splice plate or shared two-sided rafter cleat. Leave a 4 to 6 mm thermal gap between opposing purlin ends on long building runs.
Is an existing die ready for 210 × 80 × 5 mm purlin orders?
Yes, 210 × 80 × 5 mm runs on an existing die in our partner-factory network alongside 210 × 55 × 5 mm and 210 × 85 × 5 mm companion profiles. Submit roof bay lengths and cleat hole layouts on your section drawing to schedule cut-to-length production.