Geometry & mass
What are the nominal section properties and unit weight of 100 × 100 × 6 mm FRP angle?
Calculated from nominal millimetre dimensions before corner-fillet deductions, alongside equivalent S275 steel and 6063-T6 aluminum masses.
| Property | Metric value | Imperial / engineering note |
|---|---|---|
| Nominal designation | 100 × 100 × 6 mm | Leg A × leg B × thickness (mm) |
| Inch equivalent | 3.94 × 3.94 × 0.24 in | Converted at 25.4 mm/in |
| Cross-sectional area (A) | 1,164 mm² | 1.80 in² (sharp-corner nominal) |
| FRP unit mass (at 1.9 g/cm³) | 2.21 kg/m | 1.49 lb/ft planning weight |
| Same-size S275 carbon steel mass | 9.14 kg/m | FRP saves 76% deadweight |
| Same-size 6063-T6 aluminum mass | 3.14 kg/m | FRP is 30% lighter than aluminum |
| Major-axis second moment (Ixx) | 114.4 cm⁴ | 2.75 in⁴ |
| Minor-axis second moment (Iyy) | 114.4 cm⁴ | Ratio Ixx / Iyy = 1.00 |
| Elastic section modulus (Sxx / Syy) | 15.7 / 15.7 cm³ | Extreme-fibre bending modulus |
| Radius of gyration (rx / ry) | 31.3 / 31.3 mm | Used for axial column slenderness L/r |
| External perimeter | 400 mm | Surface veil and coating perimeter |
| Tooling status | Existing die (partner factory) | Pultruded to order; no new die charge |
Square-corner geometry at 1.9 g/cm³ gives A = 1,164 mm² and 2.21 kg/m (1.49 lb/ft), saving 76 percent mass against 9.14 kg/m carbon steel L100×100×6 and 30 percent against 3.14 kg/m aluminum. Symmetric axes provide Ixx = Iyy = 114.4 cm⁴ and Sxx = Syy = 15.7 cm³, with the centroid sitting 27.2 mm from each outer heel.
Geometric radius of gyration climbs to rx = ry = 31.3 mm and minor principal radius reaches rv = 19.9 mm, cutting global column slenderness over medium lengths. However, the 16.7 leg width-to-thickness ratio means local torsional-flexural leg buckling governs unbraced compression struts well before material compressive failure.
Preliminary stiffness check
How much does 100 × 100 × 6 mm FRP angle deflect across typical spans under E17 and E23 grades?
Euler bending estimates about the major axis (Ixx = 114.4 cm⁴) under a 1 kN/m uniform line load, comparing EN 13706-2 Grade E17 (17 GPa) and Grade E23 (23 GPa) minimum longitudinal moduli.
| Simple span (L) | Deflection at 1 kN/m (E17: 17 GPa) | Deflection at 1 kN/m (E23: 23 GPa) | Load for L/180 (E23) | Load for L/240 (E23) |
|---|---|---|---|---|
| 1.2 m (1200 mm) | 1.4 mm (L/864) | 1.0 mm (L/1169) | 6.50 kN/m | 4.87 kN/m |
| 1.8 m (1800 mm) | 7.0 mm (L/256) | 5.2 mm (L/346) | 1.92 kN/m | 1.44 kN/m |
| 2.4 m (2400 mm) | 22.2 mm (L/108) | 16.4 mm (L/146) | 0.81 kN/m | 0.61 kN/m |
Under a 1.0 kN/m uniform load, simple-span Euler deflection measures 1.0 to 1.4 mm at 1.2 m and 5.2 to 7.0 mm at 1.8 m (L/346 to L/259 for 23 to 17.2 GPa), reaching 16.4 to 22.0 mm across 2.4 m. Spans up to 1.8 m remain comfortably within L/240 when top-flange rotation is restrained by attached panels or grating clips.
Because an outstanding 100 × 6 mm leg has b/t = 16.7, avoid applying heavy eccentric point loads near the outer 25 mm of an unbacked horizontal flange without stiffener blocks. When cast or anchored along a concrete sump rebate as a continuous grating curb, the concrete backing eliminates twisting and engages full bearing width.
Run point loads, cantilevers or shear-corrected Timoshenko checks in the FRP section properties & deflection calculator, and verify material grade testing in EN 13706 & ASTM D3917 profile standards.
Fasteners & mating tolerances
How are single-row M16 or staggered M12 bolts laid out on 100 mm FRP legs?
A single fastener row uses M12 or M16 stainless bolts along a 55 to 60 mm gauge from the outer heel, leaving a generous 40 to 45 mm margin to the free toe and broad flat bearing well clear of the inside corner fillet. That wide bearing shelf accommodates 38 mm grating panel overlap while keeping anchor heads flush below or clear behind the panel edge.
For high-load truss chords or wide splice plates, the 100 mm face accepts a staggered two-line layout using M10 or M12 bolts on 40 mm inner and 70 mm outer gauges (30 mm transverse spacing and 30 mm toe margin) with 55 to 65 mm longitudinal stagger. Always back field-bolted splices with flat stainless or FRP cover straps across both legs where axial tension exceeds single-leg eccentricity limits.
| Interface or feature | Drawing & assembly specification |
|---|---|
| Single-line bolt gauge | 55 to 60 mm from outer heel for M12 (13 mm hole) or M16 (17.5 mm hole), leaving 40 to 45 mm toe distance. |
| Staggered two-line gauge | Inner row at 40 mm and outer row at 70 mm from heel for M10 or M12 hardware with 60 mm longitudinal stagger. |
| Grating curb bearing | Provides 50 to 65 mm clear horizontal seat for 38 mm or 50 mm molded/pultruded grating panels plus expansion gap. |
| Concrete embed anchors | Bolt M12 headed studs or bent stainless straps along the vertical leg at 450 to 600 mm centers for cast-in trench kerbs. |
Shop tooling, diamond blades and bonded-bolted joint layout: how to cut, drill and join fiberglass profiles.
Request a quotation
Get a quotation for 100 × 100 × 6 mm FRP angle
Send your cut lengths, piece count, resin system and destination port. An engineer in Shanghai reviews the schedule and replies in English.
Prefer email or chat? Write to inquiry@pultrx.com or message Celion on WhatsApp. Drawings can follow by email.
Service environments & resin selection
Where is 100 × 100 × 6 mm angle used in wastewater and coastal infrastructure?
Treatment plants install 100 × 100 × 6 mm angle as cast-in or post-fixed concrete trench grating curbs, flat odor-control cover perimeter frames and wide baffle wall corner trims where 50 mm or 75 mm seats leave insufficient bearing overlap after concrete tolerances. Along seawalls, finger piers and desalination intakes, it frames utility pipe trays and non-corroding walkway edge kerbs.
Salt-spray splash zones paired with intense solar UV call for UV-stabilized isophthalic polyester or vinyl ester finished with a synthetic surface veil to prevent fiber bloom. If unbraced compression struts over 2.0 m are subject to multi-axis wind or wave impact, switch from an open 100 mm angle to a closed 75 × 75 × 6 mm or 100 × 100 × 6 mm square tube.
Compare adjacent metric dies
Other metric angle engineering sheets
- 50 × 50 × 6 mm FRP angleCompact 6 mm thick equal-leg metric angle (1.07 kg/m, Ixx 13.1 cm⁴) for stiff equipment cleats, battery rack framing and cable-tray wall brackets.
- 75 × 75 × 6 mm FRP angleMedium-duty 75 mm metric equal angle (1.64 kg/m, Ixx 46.9 cm⁴) sized for M12 bolted gussets, cooling-tower diagonals and chemical duct stiffeners.
- 75 × 75 × 8 mm FRP angleHeavy-wall 8 mm metric equal angle (2.16 kg/m, Ixx 60.2 cm⁴) built for high bolt-bearing shear cleats, submerged weir ledges and fill-pack supports.
- 100 × 50 × 5 mm FRP unequal angleDirectional 2:1 metric unequal angle (1.38 kg/m, Ixx 76.7 cm⁴ vs Iyy 13.6 cm⁴) for rainscreen sub-girts, solar PV rail adapters and slim-flange lintels.
FAQ
What do buyers ask before ordering 100 × 100 × 6 mm FRP angle?
Can 100 × 100 × 6 mm FRP angle be cast directly into concrete trench rebates?
Yes, FRP curb angles avoid the thermal expansion mismatch spalling and chloride rust jacking common with galvanized steel embeds in wet sumps. Fit stainless headed shear anchors through the vertical leg at 450 to 600 mm pitch and tape the inside seating face clean before placement.
Does the 16.7 leg-to-thickness ratio limit axial column capacity?
Yes, an unbraced 100 × 6 mm leg crinkles in local torsional-flexural mode at lower compressive stress than stockier 75 × 75 × 8 mm (b/t = 9.4) despite having a larger radius of gyration. Use 100 × 100 × 6 mm primarily for laterally braced curbs, tension braces and wide-seat flexural members, or choose square tube for freestanding posts.
How much bearing overlap does 38 mm FRP grating need on a 100 mm curb angle?
Standard fiberglass grating layouts call for at least 30 to 40 mm of flat bearing support at panel ends plus a 6 mm clearance gap to the vertical leg. A 100 mm horizontal leg leaves ample room even when concrete wall alignment varies by 10 to 15 mm along long channels.
What fastener alloy should pair with FRP angle on coastal piers?
Grade 316 (A4) stainless steel suits atmospheric marine splash zones, while duplex 2205 or super-duplex hardware is specified for warm seawater immersion or brine outfall structures. Because E-glass FRP is an electrical insulator, stainless fasteners suffer zero galvanic acceleration from the profile itself.
What shipping lengths fit standard ocean containers?
Mill production cuts up to 5.8 m load straight into 20-foot dry containers and lengths up to 11.8 m fit 40-foot containers without splice joints. Including exact piece lengths on your section drawing reduces site sawing waste and dust containment work.