100 × 50 × 5 mm FRP unequal angle

The 100 × 50 × 5 mm FRP unequal angle concentrates structural depth along a 100 mm web while keeping the mounting flange down to 50 mm, running on an existing partner-factory die at just 1.38 kg/m (0.93 lb/ft). Oriented with the 100 mm leg parallel to the load plane, it achieves 63 percent more bending inertia than 75 × 75 × 6 mm equal angle while weighing 16 percent less per metre. Building-envelope and solar engineers specify it as a low-conductivity sub-girt and purlin cleat.

  • 1.38 kg/m (0.93 lb/ft) nominal at 1.9 g/cm³
  • Ixx = 76.7 cm⁴ · Sxx = 11.9 cm³
  • Existing die in our partner-factory network
  • Shape family: Angle requirements
100 × 50 × 5 mm FRP unequal angle cross-section drawing with dimensions in mm, area and mass per metre

To-scale angle cross-section · dimensions in mm

Area (A)
725 mm²
Gyration (rx / ry)
32.5 / 13.7 mm

Geometry & mass

What are the nominal section properties and unit weight of 100 × 50 × 5 mm FRP unequal angle?

Calculated from nominal millimetre dimensions before corner-fillet deductions, alongside equivalent S275 steel and 6063-T6 aluminum masses.

Geometric and mass properties for 100 × 50 × 5 mm FRP unequal angle
PropertyMetric valueImperial / engineering note
Nominal designation100 × 50 × 5 mmLeg A × leg B × thickness (mm)
Inch equivalent3.94 × 1.97 × 0.20 inConverted at 25.4 mm/in
Cross-sectional area (A)725 mm²1.12 in² (sharp-corner nominal)
FRP unit mass (at 1.9 g/cm³)1.38 kg/m0.93 lb/ft planning weight
Same-size S275 carbon steel mass5.69 kg/mFRP saves 76% deadweight
Same-size 6063-T6 aluminum mass1.96 kg/mFRP is 30% lighter than aluminum
Major-axis second moment (Ixx)76.7 cm⁴1.84 in⁴
Minor-axis second moment (Iyy)13.6 cm⁴Ratio Ixx / Iyy = 5.64
Elastic section modulus (Sxx / Syy)11.9 / 3.4 cm³Extreme-fibre bending modulus
Radius of gyration (rx / ry)32.5 / 13.7 mmUsed for axial column slenderness L/r
External perimeter300 mmSurface veil and coating perimeter
Tooling statusExisting die (partner factory)Pultruded to order; no new die charge

Cross-sectional area totals 725 mm², yielding 1.38 kg/m (0.93 lb/ft) at 1.9 g/cm³ versus 5.69 kg/m in steel and 1.96 kg/m in aluminum. With the 100 mm leg standing vertical, major-axis properties reach Ixx = 76.7 cm⁴, Sxx = 11.9 cm³ and rx = 32.5 mm; across the 50 mm leg, minor geometric values drop to Iyy = 13.6 cm⁴, Syy = 3.4 cm³ and ry = 13.7 mm (a 5.6:1 stiffness ratio).

The centroid lies 35.3 mm from the outer heel along the 100 mm leg and 10.3 mm from the heel along the 50 mm leg, rotating the principal bending axes by roughly 14.5 degrees (rv = 10.9 mm). Fabrication drawings must mark LLV (long leg vertical) or LLH (long leg horizontal) explicitly so shop drilling lands on the intended face.

Preliminary stiffness check

How much does 100 × 50 × 5 mm FRP unequal angle deflect across typical spans under E17 and E23 grades?

Euler bending estimates about the major axis (Ixx = 76.7 cm⁴) under a 0.75 kN/m uniform line load, comparing EN 13706-2 Grade E17 (17 GPa) and Grade E23 (23 GPa) minimum longitudinal moduli.

Simple-span Euler deflection and uniform load limits for 100 × 50 × 5 mm FRP unequal angle
Simple span (L)Deflection at 0.75 kN/m (E17: 17 GPa)Deflection at 0.75 kN/m (E23: 23 GPa)Load for L/180 (E23)Load for L/240 (E23)
1.0 m (1000 mm)0.7 mm (L/1336)0.6 mm (L/1807)7.53 kN/m5.65 kN/m
1.5 m (1500 mm)3.8 mm (L/396)2.8 mm (L/535)2.23 kN/m1.67 kN/m
2.0 m (2000 mm)12.0 mm (L/167)8.9 mm (L/226)0.94 kN/m0.71 kN/m

With the 100 mm leg vertical under a 0.75 kN/m uniform load, Euler deflection is under 0.8 mm at 1.0 m, 2.8 to 3.8 mm at 1.5 m (L/535 to L/400 across 23 to 17.2 GPa), and 8.9 to 11.8 mm at 2.0 m (L/226 to L/169). Flipping the section flat (50 mm leg vertical) multiplies mid-span sag by 5.6 times under the same load.

Because the 100 mm leg carries a slender 20:1 width-to-thickness ratio and asymmetric shear center, unrestrained beams twist laterally when the free 100 mm toe is in flexural compression. Orienting the 50 mm flange on top where cladding panels, decking or solar module rails screw into it braces the compression zone continuously.

Run point loads, cantilevers or shear-corrected Timoshenko checks in the FRP section properties & deflection calculator, and verify material grade testing in EN 13706 & ASTM D3917 profile standards.

Fasteners & mating tolerances

How do hole gauges differ between the 100 mm web and 50 mm flange?

Treat the two legs with separate fastener rules: on the 50 mm flange, restrict hardware to M8 (9 mm hole) or M10 (11 mm hole) along a 28 mm gauge from the outer heel so at least 22 mm of toe edge remains and 20 mm washers clear the inside root radius. Avoid slotting the 50 mm leg transversely, which leaves too little net tension width.

On the 100 mm leg, M10 or M12 bolts seat cleanly at a 50 to 60 mm single gauge, or in two rows at 38 mm and 72 mm from the heel when fixing cantilevered facade brackets to concrete backup walls. Slotted thermal-movement holes (for example 11 × 20 mm) belong in the 100 mm leg aligned parallel to the profile axis at sliding expansion points.

Connection and interface details for 100 × 50 × 5 mm FRP unequal angle
Interface or featureDrawing & assembly specification
50 mm flange boltingM8 or M10 hardware at 28 mm gauge from heel; 22 mm toe margin and 16 to 20 mm OD flat washers.
100 mm web boltingM10 or M12 hardware at 55 mm single gauge, or twin lines at 38 mm and 72 mm from outer heel.
Orientation calloutMark LLV (100 mm vertical) or LLH (100 mm horizontal) plus heel direction on every fabrication view.
Thermal conductivityThrough-thickness conductivity around 0.3 to 0.4 W/(m·K) cuts wall U-value bridging compared with 160 W/(m·K) aluminum.

Shop tooling, diamond blades and bonded-bolted joint layout: how to cut, drill and join fiberglass profiles.

Request a quotation

Get a quotation for 100 × 50 × 5 mm FRP unequal angle

Send your cut lengths, piece count, resin system and destination port. An engineer in Shanghai reviews the schedule and replies in English.

Prefer email or chat? Write to inquiry@pultrx.com or message Celion on WhatsApp. Drawings can follow by email.

Quotation request details

A few short fields, optional section drawings and one line about what you need.

PDF, DXF, DWG, STEP, IGES, PNG, JPG or WebP. Up to 3 files, 4 MB total. Larger CAD files can follow to inquiry@pultrx.com.

Service environments & resin selection

Why use 100 × 50 × 5 mm unequal angle in facades and solar PV racks?

Ventilated rainscreen facades pair the 100 mm standoff leg with mineral-wool insulation depths (80 to 120 mm cavities) while the 50 mm outer flange provides a flat screw or rivet rail for fiber-cement, HPL or metal cladding sub-rails. Unlike extruded aluminum helping-hand brackets, pultruded E-glass carries roughly 1/400th the thermal conductivity, slashing linear chi-value thermal bridging.

Commercial rooftop and carport solar PV integrators bolt the 50 mm flange to ballast blocks or purlins and clamp module rails along the stiff 100 mm web to achieve tilt or clear roof seams without heavy steel channels. Specify fire-retardant halogenated or ATH-filled resin systems when building facade regulations govern smoke and flame spread inside wall cavities.

Compare adjacent metric dies

Other metric angle engineering sheets

FAQ

What do buyers ask before ordering 100 × 50 × 5 mm FRP unequal angle?

Which way up should 100 × 50 × 5 mm angle sit when spanning horizontally?

Keep the 100 mm leg vertical to mobilize Ixx = 76.7 cm⁴, and place the 50 mm horizontal flange on the compression edge (top face for downward gravity or snow loads) where attached panels or rails restrain lateral twist. If uplift wind suction reverses compression into the bottom free toe, add anti-roll cleats at supports.

How does thermal expansion compare with aluminum cladding rails?

Longitudinal thermal expansion of pultruded E-glass FRP sits around 8 to 11 × 10⁻⁶ /K, close to concrete and carbon steel and less than half that of aluminum (23 × 10⁻⁶ /K). Even so, provide fixed-and-sliding hole slots on 3.0 m sub-girt sticks when metal cladding skins expand across them.

Can self-drilling screws fasten cladding directly into the 5 mm flange?

Through-bolting with stainless M8 bolts and locknuts or structural blind rivets with wide backup tails gives far more reliable pull-out resistance under cyclic wind suction than thread-forming sheet-metal screws in 5 mm pultruded walls. Always validate pull-out and pull-over values on project-specific laminate coupons if blind fasteners are planned.

Is 100 × 50 × 5 mm unequal angle produced on an existing partner die?

Yes, 100 × 50 × 5 mm is one of seven confirmed metric unequal-leg angles on existing dies in our partner-factory network, alongside sizes such as 50 × 30 × 5 mm and 135 × 70 × 6 mm. Runs are pultruded to order in architectural gray, black or custom colors.

What fire-retardant resin options exist for ventilated wall cavities?

Partner factories run flame-retardant isophthalic polyester, vinyl ester and phenolic-modified or ATH-filled systems formulated to meet specified project fire test targets. Include the exact target standard and thickness coupon requirement on your section drawing before sample pultrusion.

Send a cross-section drawing. Get a scoped quotation.

Every quotation names the manufacturer, the exporter of record and the warranty party, and lists what is included.