Geometry & mass
What are the nominal section properties and unit weight of 100 × 100 × 8 mm FRP square tube?
Calculated from nominal millimetre dimensions before corner-fillet deductions, alongside equivalent S275 steel and 6063-T6 aluminum masses.
| Property | Metric value | Imperial / engineering note |
|---|---|---|
| Nominal designation | 100 × 100 × 8 mm | Side × side × wall (mm) |
| Inch equivalent | 3.94 × 3.94 × 0.31 in | Converted at 25.4 mm/in |
| Cross-sectional area (A) | 2,944 mm² | 4.56 in² (sharp-corner nominal) |
| FRP unit mass (at 1.9 g/cm³) | 5.59 kg/m | 3.76 lb/ft planning weight |
| Same-size S275 carbon steel mass | 23.11 kg/m | FRP saves 76% deadweight |
| Same-size 6063-T6 aluminum mass | 7.95 kg/m | FRP is 30% lighter than aluminum |
| Major-axis second moment (Ixx) | 418.4 cm⁴ | 10.05 in⁴ |
| Minor-axis second moment (Iyy) | 418.4 cm⁴ | Ratio Ixx / Iyy = 1.00 |
| Elastic section modulus (Sxx / Syy) | 83.7 / 83.7 cm³ | Extreme-fibre bending modulus |
| Radius of gyration (rx / ry) | 37.7 / 37.7 mm | Used for axial column slenderness L/r |
| External perimeter | 400 mm | Surface veil and coating perimeter |
| Tooling status | Existing die (partner factory) | Pultruded to order; no new die charge |
At 1.9 g/cm³ nominal density, the 2,944 mm² wall area weighs 5.59 kg/m (3.76 lb/ft), cutting member deadweight by 76 percent relative to an equivalent 100 × 100 × 8 mm carbon steel SHS at 23.11 kg/m and 30 percent below aluminum at 7.95 kg/m.
Symmetric section moduli of Sxx = Syy = 83.7 cm³ and radii of gyration rx = ry = 37.7 mm keep column slenderness KL/r below 80 across a 3.0 m unbraced storey height in both orthogonal planes.
Preliminary stiffness check
How much does 100 × 100 × 8 mm FRP square tube deflect across typical spans under E17 and E23 grades?
Euler bending estimates about the major axis (Ixx = 418.4 cm⁴) under a 2 kN/m uniform line load, comparing EN 13706-2 Grade E17 (17 GPa) and Grade E23 (23 GPa) minimum longitudinal moduli.
| Simple span (L) | Deflection at 2 kN/m (E17: 17 GPa) | Deflection at 2 kN/m (E23: 23 GPa) | Load for L/180 (E23) | Load for L/240 (E23) |
|---|---|---|---|---|
| 2.0 m (2000 mm) | 5.9 mm (L/341) | 4.3 mm (L/462) | 5.13 kN/m | 3.85 kN/m |
| 3.0 m (3000 mm) | 29.7 mm (L/101) | 21.9 mm (L/137) | 1.52 kN/m | 1.14 kN/m |
| 4.0 m (4000 mm) | 93.7 mm (L/43) | 69.3 mm (L/58) | 0.64 kN/m | 0.48 kN/m |
Under a 2.0 kN/m uniform line load at 23 GPa longitudinal modulus, pure Euler mid-span deflection rises from roughly 4.3 mm on a 2.0 m span (L/462) to 21.9 mm at 3.0 m (L/137), so floor joists carrying pedestrian live load normally stay at or below 2.5 m centers.
Because the 8 mm closed box wall yields a compact flat-width-to-thickness ratio near 10.5, local plate buckling never precedes global column flexure or overall beam deflection under standard service loads.
At short 2.0 m spans where the span-to-depth ratio L/h equals 20, interlaminar shear deformation adds roughly 8 to 11 percent onto the Euler bending figure and should be included in ledger check calculations.
Run point loads, cantilevers or shear-corrected Timoshenko checks in the FRP section properties & deflection calculator, and verify material grade testing in EN 13706 & ASTM D3917 profile standards.
Fasteners & mating tolerances
How do you detail baseplates and through-bolts on 100 × 100 × 8 mm FRP square tube?
An 8 mm wall develops substantial pin-bearing resistance around M12 or M16 stainless bolts, yet hollow tubes still flatten if installers over-torque through-bolts across an unsupported 84 mm cavity. Fit galvanized or stainless steel compression sleeves, or bond a solid pultruded block inside the 84 × 84 mm core at heavy truss nodes and moment-resisting base shoes.
Keep bolt centerlines at least 28 to 32 mm back from cut tube ends (3.5 to 4 times bolt diameter) and maintain 25 mm minimum edge distance from outside corners so holes stay clear of the internal pultrusion fillet radius.
| Interface or feature | Drawing & assembly specification |
|---|---|
| Outside envelope | 100 × 100 mm square exterior; fits dual-gusset steel or FRP base shoes with 102 mm clear jaw width and 1 mm adhesive or shim allowance per face. |
| Internal clear bore | 84 × 84 mm nominal flat-to-flat cavity; chamfer corners 4 to 5 mm on machined splice spigots to clear the internal roving fillet. |
| Recommended fasteners | M12 or M16 A4-70 / 316 stainless bolts in 13 or 17.5 mm drilled holes with DIN 9021 wide washers and internal crush-control ferrules. |
| Column end bearing | 2,944 mm² milled end area bears uniformly against flat baseplates; seal saw-cut ends with catalyzed resin before wet cooling-tower installation. |
Shop tooling, diamond blades and bonded-bolted joint layout: how to cut, drill and join fiberglass profiles.
Request a quotation
Get a quotation for 100 × 100 × 8 mm FRP square tube
Send your cut lengths, piece count, resin system and destination port. An engineer in Shanghai reviews the schedule and replies in English.
Prefer email or chat? Write to inquiry@pultrx.com or message Celion on WhatsApp. Drawings can follow by email.
Service environments & resin selection
Where is 100 × 100 × 8 mm square tube chosen over 6 mm or 9 mm walls?
Counterflow and crossflow cooling tower erectors specify 100 × 100 × 8 mm posts in lower basin zones where basin spray, plume condensation, chlorination chemicals and high axial fan-deck loads converge. Isophthalic polyester with UV inhibitor handles treated cooling water, whereas vinyl ester resin is selected when blowdown chemistry turns acidic or brackish.
Stepping up from the lighter 100 × 100 × 6 mm existing die raises bolt bearing thickness by 33 percent and lifts Ixx from 336.0 to 418.4 cm⁴ without changing external bracket tooling. Where extreme axial load governs within the same 100 mm footprint, a 100 × 100 × 9 mm existing die is also available; if bending stiffness per kilogram dominates instead, moving to a 127 × 127 × 6 mm tube raises inertia at comparable mass.
Compare adjacent metric dies
Other metric square tube engineering sheets
- 50 × 50 × 5 mm FRP square tubeStandard 50 mm metric hollow box section (40 × 40 mm bore, 1.71 kg/m, Ixx 30.8 cm⁴) for industrial guardrail posts, top rails and treatment-plant barriers.
- 50 × 50 × 6 mm FRP square tubeThick-wall 6 mm metric 50 mm square tube (38 × 38 mm bore, 2.01 kg/m, Ixx 34.7 cm⁴) engineered for bored ladder stringers and high-load chemical stanchions.
- 60 × 60 × 4 mm FRP square tubeHigh-efficiency 60 mm thin-wall square tube (52 × 52 mm bore, 1.70 kg/m, Ixx 47.1 cm⁴) giving 53 percent more stiffness than 50 × 50 × 5 mm at equal mass.
- 75 × 75 × 6 mm FRP square tubePrimary 75 mm metric structural box column (63 × 63 mm bore, 3.15 kg/m, Ixx 132.4 cm⁴) for field-erected cooling towers, stair newels and platform bents.
- 80 × 80 × 5 mm FRP square tubeModular 80 mm metric box section (70 × 70 mm bore, 2.85 kg/m, Ixx 141.2 cm⁴) matching 75 × 75 × 6 mm section modulus at 9.5 percent lower weight.
- 100 × 100 × 6 mm FRP square tubeHeavy 100 mm metric box column and header (88 × 88 mm bore, 4.29 kg/m, Ixx 333.6 cm⁴) offering 2.52 times the stiffness of 75 × 75 × 6 mm square tube.
- 150 × 150 × 4.5 mm FRP square tubeWide-profile, thin-wall 150 × 150 × 4.5 mm square hollow section (4.98 kg/m, Ixx 925.0 cm⁴) engineered for RF-transparent radome spaceframes, architectural louvres and long-span light enclosures.
FAQ
What do buyers ask before ordering 100 × 100 × 8 mm FRP square tube?
Does 100 × 100 × 8 mm FRP square tube require new die tooling?
No new tooling is needed because 100 × 100 × 8 mm runs on an existing die in our partner-factory network. Profiles are pultruded to order in project cut lengths, and the order schedule names the producing factory, resin system and minimum run length.
What axial column load can a 3 m post of 100 × 100 × 8 mm carry?
With rx = ry = 37.7 mm and Ixx = 418.4 cm⁴, the theoretical pinned-end Euler buckling load across a 3.0 m unbraced height is roughly 105 kN at 23 GPa longitudinal modulus before shear reduction and safety factors. After applying standard FRP column interaction factors (typically 2.5 to 3.0) and wet-service knockdown, engineers regularly qualify working axial loads in the 25 to 35 kN range.
Will standard 80 × 80 mm FRP square tube telescope inside the 84 × 84 mm bore?
An 80 × 80 mm tube leaves 2 mm nominal clearance per side across the 84 × 84 mm flat opening, which works well for a bonded structural splice sleeve using two-part epoxy or methacrylate paste adhesive. Always check corner fillet interference on a short offcut before specifying long telescopic overlaps on fabrication drawings.
How does Henan Zhongsheng control straightness and cut squareness on heavy 8 mm tubes?
Heavy 8 mm walls require slower pull speeds and controlled exotherm curing inside the heated die so residual bow stays within EN 13706 tolerances. Partner plants such as Henan Zhongsheng saw-cut column lengths on fixture stops so milled ends sit square on baseplates without point-edge crushing.
Should cooling tower columns in this size include surface veil and fire retardant?
Yes, cooling tower specifications normally pair a polyester synthetic surface veil against UV fiber bloom with halogen-free or brominated fire-retardant resin meeting ASTM E84 Class 1 flame spread limits. State any flame-spread index or basin water pH range on your purchase order so the resin formulation matches plant insurance rules.