Skip to content
pultrx

Metric square tube · Existing die · Updated 2026-11-18

50 × 50 × 5 mm FRP square tube

The 50 × 50 × 5 mm FRP square tube is the core metric profile for modular industrial guardrails and light access frames, pultruded on an existing partner-factory die with a 40 × 40 mm nominal internal opening and 1.71 kg/m (1.15 lb/ft) mass. Its closed four-wall box section delivers identical bending stiffness (Ixx = Iyy = 30.8 cm⁴) across both axes plus high St. Venant torsional rigidity absent in open angles or channels. Fabricators pair it with molded 50 mm elbows and stainless base stanchions across corrosive wet-process walkways.

  • 1.71 kg/m (1.15 lb/ft) nominal at 1.9 g/cm³
  • Ixx = 30.8 cm⁴ · Sxx = 12.3 cm³
  • Existing die in our partner-factory network
  • Shape family: Square tube requirements
50 × 50 × 5 mm FRP square tube cross-section drawing with dimensions in mm, area and mass per metre

To-scale square tube cross-section · dimensions in mm

Area (A)
900 mm²
Gyration (rx / ry)
18.5 / 18.5 mm

Geometry & mass

What are the nominal section properties and unit weight of 50 × 50 × 5 mm FRP square tube?

Calculated from nominal millimetre dimensions before corner-fillet deductions, alongside equivalent S275 steel and 6063-T6 aluminum masses.

Geometric and mass properties for 50 × 50 × 5 mm FRP square tube
PropertyMetric valueImperial / engineering note
Nominal designation50 × 50 × 5 mmSide × side × wall (mm)
Inch equivalent1.97 × 1.97 × 0.20 inConverted at 25.4 mm/in
Cross-sectional area (A)900 mm²1.40 in² (sharp-corner nominal)
FRP unit mass (at 1.9 g/cm³)1.71 kg/m1.15 lb/ft planning weight
Same-size S275 carbon steel mass7.07 kg/mFRP saves 76% deadweight
Same-size 6063-T6 aluminum mass2.43 kg/mFRP is 30% lighter than aluminum
Major-axis second moment (Ixx)30.8 cm⁴0.74 in⁴
Minor-axis second moment (Iyy)30.8 cm⁴Ratio Ixx / Iyy = 1.00
Elastic section modulus (Sxx / Syy)12.3 / 12.3 cm³Extreme-fibre bending modulus
Radius of gyration (rx / ry)18.5 / 18.5 mmUsed for axial column slenderness L/r
External perimeter200 mmSurface veil and coating perimeter
Tooling statusExisting die (partner factory)Pultruded to order; no new die charge

Nominal cross-sectional area is 900 mm², yielding 1.71 kg/m (1.15 lb/ft) at 1.9 g/cm³ versus 7.06 kg/m for steel SHS 50×50×5 and 2.43 kg/m for aluminum, closely matching inch-series 2 × 2 × 3/16 in tube (50.8 × 50.8 × 4.76 mm). Elastic properties equal Ixx = Iyy = 30.8 cm⁴ and Sxx = Syy = 12.3 cm³.

Radius of gyration reaches rx = ry = 18.5 mm in every plane, and the compact 10:1 flat-wall ratio resists local face dimpling under normal guardrail clamp loads. Compared with 50 × 50 × 6 mm equal angle, this closed 50 mm square section supplies 2.35 times the flexural inertia for only 60 percent more linear weight.

Preliminary stiffness check

How much does 50 × 50 × 5 mm FRP square tube deflect across typical spans under E17 and E23 grades?

Euler bending estimates about the major axis (Ixx = 30.8 cm⁴) under a 0.8 kN/m uniform line load, comparing EN 13706-2 Grade E17 (17 GPa) and Grade E23 (23 GPa) minimum longitudinal moduli.

Simple-span Euler deflection and uniform load limits for 50 × 50 × 5 mm FRP square tube
Simple span (L)Deflection at 0.8 kN/m (E17: 17 GPa)Deflection at 0.8 kN/m (E23: 23 GPa)Load for L/180 (E23)Load for L/240 (E23)
1.0 m (1000 mm)2.0 mm (L/502)1.5 mm (L/679)3.02 kN/m2.26 kN/m
1.5 m (1500 mm)10.1 mm (L/149)7.5 mm (L/201)0.89 kN/m0.67 kN/m
2.0 m (2000 mm)31.9 mm (L/63)23.6 mm (L/85)0.38 kN/m0.28 kN/m

Across horizontal rail spans under a 0.8 kN/m uniform load, Euler deflection measures 1.5 to 2.0 mm at 1.0 m and 7.4 to 10.0 mm at 1.5 m (L/202 to L/151 for 23 to 17.2 GPa), climbing to 23.5 to 31.5 mm at 2.0 m. Keeping guardrail post spacing between 1.2 and 1.5 m controls horizontal top-rail flex comfortably.

When evaluated as a 1.1 m cantilevered guardrail post carrying concentrated lateral rail loads, root bending and web shear act together while socket base play adds rigid-body tilt. Snug-fitting internal steel base spigots bonded or cross-bolted at two heights cut top-of-post sway markedly compared with loose slip-fit boots.

Run point loads, cantilevers or shear-corrected Timoshenko checks in the FRP section properties & deflection calculator, and verify material grade testing in EN 13706 & ASTM D3917 profile standards.

Fasteners & mating tolerances

How do base spigots, corner elbows and through-bolts fit 50 × 50 × 5 mm tube?

The nominal clear flat-to-flat opening is 40 × 40 mm, while internal pultrusion corners carry a small fillet radius. Machine solid FRP or stainless baseplate spigot plugs to 38.5 to 39.0 mm square with 3 mm 45-degree corner bevels and at least 150 to 200 mm embedment depth into the post base, cross-bolted with two M10 fasteners.

Avoid tightening bare M10 through-bolts across an empty 40 mm hollow core to high torque, which bows the 5 mm side walls inward and cracks longitudinal corners. Fit internal tubular crush sleeves around heavily torqued base bolts, or use snug external U-brackets and molded 50 mm square rail tees bonded with two-part structural adhesive.

Connection and interface details for 50 × 50 × 5 mm FRP square tube
Interface or featureDrawing & assembly specification
Internal clear bore40 × 40 mm flat-to-flat nominal; bevel insert plug corners by 3 mm × 45° to clear internal die fillets.
Post base spigot38.5 to 39 mm square stainless or solid FRP stem inserted 150 to 200 mm deep with twin M10 cross-bolts at 75 mm pitch.
Through-bolt protection40 mm long × 11 mm ID stainless spacer tube inside the cavity prevents side-wall crushing under bolt preload.
Inch-fitting caution50.0 mm OD sits 0.8 mm looser per side inside 2-inch (50.8 mm) imperial molded fittings; confirm adhesive gap before mixing.

Shop tooling, diamond blades and bonded-bolted joint layout: how to cut, drill and join fiberglass profiles.

Request a quotation

Get a quotation for 50 × 50 × 5 mm FRP square tube

Send your cut lengths, piece count, resin system and destination port. An engineer in Shanghai reviews the schedule and replies in English.

Prefer email or chat? Write to inquiry@pultrx.com or message Celion on WhatsApp. Drawings can follow by email.

Quotation request details

A few short fields, optional section drawings and one line about what you need.

PDF, DXF, DWG, STEP, IGES, PNG, JPG or WebP. Up to 3 files, 4 MB total. Larger CAD files can follow to inquiry@pultrx.com.

Service environments & resin selection

Where is 50 × 50 × 5 mm square tube specified on walkways and water plants?

Municipal water and wastewater works install 50 × 50 × 5 mm square tube for aeration-basin perimeter guardrails, clarifier bridge top and mid-rails, filter-gallery safety gates and removable pump-well barriers. Safety yellow (RAL 1003/1023) pigmented throughout the resin plus a UV-stabilized surface veil eliminates repainting cycles over open basins.

Isophthalic polyester handles standard outdoor sewage treatment atmospheres and potable water plants, whereas vinyl ester is chosen around sodium hypochlorite dosing skids and ferric sulfate bunds. Where vertical ladder stiles are bored for 25 to 30 mm through-rungs or posts sit on wider centers, step up to 50 × 50 × 6 mm or 75 × 75 × 6 mm square tube.

Compare adjacent metric dies

Other metric square tube engineering sheets

FAQ

What do buyers ask before ordering 50 × 50 × 5 mm FRP square tube?

Will standard 2-inch imperial handrail fittings fit 50 × 50 × 5 mm metric tube?

A 2-inch nominal fitting pocket is sized for 50.8 mm tube, leaving an extra 0.8 mm total clearance around a 50.0 mm metric section. That gap works when filled with structural paste epoxy or shimmed, though metric 50 mm socket brackets give tighter mechanical alignment prior to bonding.

What post spacing works for 50 × 50 × 5 mm industrial walkway guardrails?

Most industrial platform layouts space 50 × 50 × 5 mm posts at 1.2 to 1.5 m centers when post height is 1.1 m above the walking surface, often sliding a solid FRP or steel core 250 mm up from the baseplate on high-load corners. Always run a project-specific deflection and root-moment check against governing plant guardrail loads.

Can a 40 × 40 mm metric FRP square tube telescope directly inside 50 × 50 × 5 mm?

Because nominal bore equals 40.0 mm and internal corners carry a pultrusion radius, a nominal 40 × 40 mm outer tube will bind on tolerances and corners without light sanding or corner dressing. For trouble-free telescoping splices without machining, use 38 × 38 × 3.5 mm square tube with a thin structural adhesive bondline.

Should horizontal guardrail tubes have weep holes in outdoor freeze-thaw climates?

Capping open tube ends with bonded FRP plugs and sealing top-face fastener penetrations keeps rainwater out of horizontal rails. On vertical posts seated into pocket shoes, drill a small 6 mm drain hole just above the internal plug top so trapped condensation cannot freeze and split the lower wall.

How is safety yellow UV resistance maintained over multi-year outdoor service?

Pigment is dispersed throughout the liquid resin matrix and covered by a synthetic polyester surface veil plus UV absorber package during pultrusion, avoiding the flaking seen on painted steel. For arid high-UV sites, an optional shop-applied aliphatic polyurethane topcoat extends gloss retention even further.

Send a cross-section drawing. Get a scoped quotation.

Every quotation names the manufacturer, the exporter of record and the warranty party, and lists what is included.