Geometry & mass
What are the nominal section properties and unit weight of 50 × 50 × 5 mm FRP square tube?
Calculated from nominal millimetre dimensions before corner-fillet deductions, alongside equivalent S275 steel and 6063-T6 aluminum masses.
| Property | Metric value | Imperial / engineering note |
|---|---|---|
| Nominal designation | 50 × 50 × 5 mm | Side × side × wall (mm) |
| Inch equivalent | 1.97 × 1.97 × 0.20 in | Converted at 25.4 mm/in |
| Cross-sectional area (A) | 900 mm² | 1.40 in² (sharp-corner nominal) |
| FRP unit mass (at 1.9 g/cm³) | 1.71 kg/m | 1.15 lb/ft planning weight |
| Same-size S275 carbon steel mass | 7.07 kg/m | FRP saves 76% deadweight |
| Same-size 6063-T6 aluminum mass | 2.43 kg/m | FRP is 30% lighter than aluminum |
| Major-axis second moment (Ixx) | 30.8 cm⁴ | 0.74 in⁴ |
| Minor-axis second moment (Iyy) | 30.8 cm⁴ | Ratio Ixx / Iyy = 1.00 |
| Elastic section modulus (Sxx / Syy) | 12.3 / 12.3 cm³ | Extreme-fibre bending modulus |
| Radius of gyration (rx / ry) | 18.5 / 18.5 mm | Used for axial column slenderness L/r |
| External perimeter | 200 mm | Surface veil and coating perimeter |
| Tooling status | Existing die (partner factory) | Pultruded to order; no new die charge |
Nominal cross-sectional area is 900 mm², yielding 1.71 kg/m (1.15 lb/ft) at 1.9 g/cm³ versus 7.06 kg/m for steel SHS 50×50×5 and 2.43 kg/m for aluminum, closely matching inch-series 2 × 2 × 3/16 in tube (50.8 × 50.8 × 4.76 mm). Elastic properties equal Ixx = Iyy = 30.8 cm⁴ and Sxx = Syy = 12.3 cm³.
Radius of gyration reaches rx = ry = 18.5 mm in every plane, and the compact 10:1 flat-wall ratio resists local face dimpling under normal guardrail clamp loads. Compared with 50 × 50 × 6 mm equal angle, this closed 50 mm square section supplies 2.35 times the flexural inertia for only 60 percent more linear weight.
Preliminary stiffness check
How much does 50 × 50 × 5 mm FRP square tube deflect across typical spans under E17 and E23 grades?
Euler bending estimates about the major axis (Ixx = 30.8 cm⁴) under a 0.8 kN/m uniform line load, comparing EN 13706-2 Grade E17 (17 GPa) and Grade E23 (23 GPa) minimum longitudinal moduli.
| Simple span (L) | Deflection at 0.8 kN/m (E17: 17 GPa) | Deflection at 0.8 kN/m (E23: 23 GPa) | Load for L/180 (E23) | Load for L/240 (E23) |
|---|---|---|---|---|
| 1.0 m (1000 mm) | 2.0 mm (L/502) | 1.5 mm (L/679) | 3.02 kN/m | 2.26 kN/m |
| 1.5 m (1500 mm) | 10.1 mm (L/149) | 7.5 mm (L/201) | 0.89 kN/m | 0.67 kN/m |
| 2.0 m (2000 mm) | 31.9 mm (L/63) | 23.6 mm (L/85) | 0.38 kN/m | 0.28 kN/m |
Across horizontal rail spans under a 0.8 kN/m uniform load, Euler deflection measures 1.5 to 2.0 mm at 1.0 m and 7.4 to 10.0 mm at 1.5 m (L/202 to L/151 for 23 to 17.2 GPa), climbing to 23.5 to 31.5 mm at 2.0 m. Keeping guardrail post spacing between 1.2 and 1.5 m controls horizontal top-rail flex comfortably.
When evaluated as a 1.1 m cantilevered guardrail post carrying concentrated lateral rail loads, root bending and web shear act together while socket base play adds rigid-body tilt. Snug-fitting internal steel base spigots bonded or cross-bolted at two heights cut top-of-post sway markedly compared with loose slip-fit boots.
Run point loads, cantilevers or shear-corrected Timoshenko checks in the FRP section properties & deflection calculator, and verify material grade testing in EN 13706 & ASTM D3917 profile standards.
Fasteners & mating tolerances
How do base spigots, corner elbows and through-bolts fit 50 × 50 × 5 mm tube?
The nominal clear flat-to-flat opening is 40 × 40 mm, while internal pultrusion corners carry a small fillet radius. Machine solid FRP or stainless baseplate spigot plugs to 38.5 to 39.0 mm square with 3 mm 45-degree corner bevels and at least 150 to 200 mm embedment depth into the post base, cross-bolted with two M10 fasteners.
Avoid tightening bare M10 through-bolts across an empty 40 mm hollow core to high torque, which bows the 5 mm side walls inward and cracks longitudinal corners. Fit internal tubular crush sleeves around heavily torqued base bolts, or use snug external U-brackets and molded 50 mm square rail tees bonded with two-part structural adhesive.
| Interface or feature | Drawing & assembly specification |
|---|---|
| Internal clear bore | 40 × 40 mm flat-to-flat nominal; bevel insert plug corners by 3 mm × 45° to clear internal die fillets. |
| Post base spigot | 38.5 to 39 mm square stainless or solid FRP stem inserted 150 to 200 mm deep with twin M10 cross-bolts at 75 mm pitch. |
| Through-bolt protection | 40 mm long × 11 mm ID stainless spacer tube inside the cavity prevents side-wall crushing under bolt preload. |
| Inch-fitting caution | 50.0 mm OD sits 0.8 mm looser per side inside 2-inch (50.8 mm) imperial molded fittings; confirm adhesive gap before mixing. |
Shop tooling, diamond blades and bonded-bolted joint layout: how to cut, drill and join fiberglass profiles.
Request a quotation
Get a quotation for 50 × 50 × 5 mm FRP square tube
Send your cut lengths, piece count, resin system and destination port. An engineer in Shanghai reviews the schedule and replies in English.
Prefer email or chat? Write to inquiry@pultrx.com or message Celion on WhatsApp. Drawings can follow by email.
Service environments & resin selection
Where is 50 × 50 × 5 mm square tube specified on walkways and water plants?
Municipal water and wastewater works install 50 × 50 × 5 mm square tube for aeration-basin perimeter guardrails, clarifier bridge top and mid-rails, filter-gallery safety gates and removable pump-well barriers. Safety yellow (RAL 1003/1023) pigmented throughout the resin plus a UV-stabilized surface veil eliminates repainting cycles over open basins.
Isophthalic polyester handles standard outdoor sewage treatment atmospheres and potable water plants, whereas vinyl ester is chosen around sodium hypochlorite dosing skids and ferric sulfate bunds. Where vertical ladder stiles are bored for 25 to 30 mm through-rungs or posts sit on wider centers, step up to 50 × 50 × 6 mm or 75 × 75 × 6 mm square tube.
Compare adjacent metric dies
Other metric square tube engineering sheets
- 50 × 50 × 6 mm FRP square tubeThick-wall 6 mm metric 50 mm square tube (38 × 38 mm bore, 2.01 kg/m, Ixx 34.7 cm⁴) engineered for bored ladder stringers and high-load chemical stanchions.
- 60 × 60 × 4 mm FRP square tubeHigh-efficiency 60 mm thin-wall square tube (52 × 52 mm bore, 1.70 kg/m, Ixx 47.1 cm⁴) giving 53 percent more stiffness than 50 × 50 × 5 mm at equal mass.
- 75 × 75 × 6 mm FRP square tubePrimary 75 mm metric structural box column (63 × 63 mm bore, 3.15 kg/m, Ixx 132.4 cm⁴) for field-erected cooling towers, stair newels and platform bents.
- 80 × 80 × 5 mm FRP square tubeModular 80 mm metric box section (70 × 70 mm bore, 2.85 kg/m, Ixx 141.2 cm⁴) matching 75 × 75 × 6 mm section modulus at 9.5 percent lower weight.
- 100 × 100 × 6 mm FRP square tubeHeavy 100 mm metric box column and header (88 × 88 mm bore, 4.29 kg/m, Ixx 333.6 cm⁴) offering 2.52 times the stiffness of 75 × 75 × 6 mm square tube.
- 100 × 100 × 8 mm FRP square tubeHeavy-wall 100 × 100 × 8 mm square hollow section (5.59 kg/m, Ixx 418.4 cm⁴) built for cooling tower columns, boardwalk substructure posts and high-bearing bolted joints.
- 150 × 150 × 4.5 mm FRP square tubeWide-profile, thin-wall 150 × 150 × 4.5 mm square hollow section (4.98 kg/m, Ixx 925.0 cm⁴) engineered for RF-transparent radome spaceframes, architectural louvres and long-span light enclosures.
FAQ
What do buyers ask before ordering 50 × 50 × 5 mm FRP square tube?
Will standard 2-inch imperial handrail fittings fit 50 × 50 × 5 mm metric tube?
A 2-inch nominal fitting pocket is sized for 50.8 mm tube, leaving an extra 0.8 mm total clearance around a 50.0 mm metric section. That gap works when filled with structural paste epoxy or shimmed, though metric 50 mm socket brackets give tighter mechanical alignment prior to bonding.
What post spacing works for 50 × 50 × 5 mm industrial walkway guardrails?
Most industrial platform layouts space 50 × 50 × 5 mm posts at 1.2 to 1.5 m centers when post height is 1.1 m above the walking surface, often sliding a solid FRP or steel core 250 mm up from the baseplate on high-load corners. Always run a project-specific deflection and root-moment check against governing plant guardrail loads.
Can a 40 × 40 mm metric FRP square tube telescope directly inside 50 × 50 × 5 mm?
Because nominal bore equals 40.0 mm and internal corners carry a pultrusion radius, a nominal 40 × 40 mm outer tube will bind on tolerances and corners without light sanding or corner dressing. For trouble-free telescoping splices without machining, use 38 × 38 × 3.5 mm square tube with a thin structural adhesive bondline.
Should horizontal guardrail tubes have weep holes in outdoor freeze-thaw climates?
Capping open tube ends with bonded FRP plugs and sealing top-face fastener penetrations keeps rainwater out of horizontal rails. On vertical posts seated into pocket shoes, drill a small 6 mm drain hole just above the internal plug top so trapped condensation cannot freeze and split the lower wall.
How is safety yellow UV resistance maintained over multi-year outdoor service?
Pigment is dispersed throughout the liquid resin matrix and covered by a synthetic polyester surface veil plus UV absorber package during pultrusion, avoiding the flaking seen on painted steel. For arid high-UV sites, an optional shop-applied aliphatic polyurethane topcoat extends gloss retention even further.